+91-84089 03000

      Standard Sales Corporation

We are Authorised Channel Distributor, Dealer, Supplier, Trader, Exporter of this product from Pune, Maharashtra, India.


1) JZ-CY



JZ-CY
Application :
For use as a data cable in control circuits in tool-making and machine industries as well as a signal cable in computer systems and electronics. The more usual PVC inner sheath has been removed in the cable, thus reducing the total diameter of the cables considerably and thereby reducing the bending radius, total weight etc. The dense screening assures disturbance-free transmission of all signals and impulses. Standard

Technical Data
  • Nominal Voltage: Uo / U 300 / 500V
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 10 x cable ø. Fixed installation5 x cable ø
  • Test Voltage: Core/core 4000V. Core/screen 2000V
  • Breakdown Voltage: Min. 8000V
  • Cable Construction



Part Number No. of Cores & Nominal
Cross Sectional Area (Sq.mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
031200201050 2 x 0.5 5.8 18.8 46
031200311050 3G 0.5 6.1 24.7 55
031200301050 3 x 0.5 6.1 24.7 55
031200411050 4G 0.5 6.6 29.2 69
031200401050 4 x 0.5 6.6 29.2 69
031200511050 5G 0.5 7.1 34.6 80
031200501050 5 x 0.5 7.1 34.6 80
031200711050 7G 0.5 7.6 45.1 99
031200701050 7 x 0.5 7.6 45.1 99
031201211050 12G 0.5 9.8 71.4 151
031201201050 12 x 0.5 9.8 71.4 151
031201811050 18G 0.5 11.3 100.1 210
031201801050 18 x 0.5 11.3 100.1 210
031202511050 25G 0.5 12.3 134.1 270
031202501050 25 x 0.5 12.3 134.1 270
031200201075 2 x 0.75 6.3 25.0 58
031200311075 3G 0.75 6.7 31.3 70
031200301075 3 x 0.75 6.7 31.3 70
031200411075 4G 0.75 7.2 39.0 84
031200401075 4 x 0.75 7.2 39.0 84
031200511075 5G 0.75 7.8 47.2 101
031200501075 5 x 0.75 7.8 47.2 101
031200711075 7G 0.75 8.4 62.0 126
031200701075 7 x 0.75 8.4 62.0 126
031201211075 12G 0.75 10.9 98.9 200
031201811075 18G 0.75 12.7 141.0 275
031202511075 25G 0.75 13.8 210.6 360
031202501075 25 x 0.75 13.8 210.6 360
031200200001 2 x 1 6.7 29.5 65
031200310001 3G 1 7.0 38.9 80
031200300001 3 x 1 7.0 38.9 80
031200410001 4G 1 7.6 49.1 100
031200400001 4 x 1 7.6 49.1 100
031200510001 5G 1 8.3 58.4 120
031200500001 5 x 1 8.3 58.4 120
031200710001 7G 1 8.9 77.2 150
031200700001 7 x 1 8.9 77.2 150
031201210001 12G 1 11.6 125.5 240
031201810001 18G 1 13.5 180.0 330
031202510001 25G 1 14.7 266.1 430
031200201105 2 x 1.5 7.3 39.4 80
031200311105 3G 1.5 7.7 51.7 100
031200301105 3 x 1.5 7.7 51.7 100
031200411105 4G 1.5 8.4 66.2 125
031200401105 4 x 1.5 8.4 66.2 125
031200511105 5G 1.5 9.1 80.9 150
031200501105 5 x 1.5 9.1 80.9 150
031200711105 7G 1.5 9.9 108.0 190
031200701105 7 x 1.5 9.9 108.0 190
031201211105 12G 1.5 12.9 175.1 285
031201811105 18G 1.5 15.1 276.0 435
031202511105 25G 1.5 16.7 377.6 590
031203411105 34G 1.5 20.4 488.3 800

2) JZ-YCY

JZ-YCY
Application : For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses.
Standard Requirements adapted to DIN VDE 0245, 0281 Part 13.

Technical Data
  • Nominal Voltage: U / U 300 / 500V
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø
  • Test Voltage: 4000V



Part Number No. of Cores and NominalCross Sectional Area (Sq. mm) Approx. CableDiameter (mm) Approx. CopperWeight (kg/km) Approx. CableWeight (kg/km)
031000201050 2 x 0.5 7.1 21.6 76
031000311050 3G 0.5 7.5 27.6 85
031000301050 3 X 0.5 7.5 27.6 85
031000411050 4G 0.5 8.0 32.5 ‘99
031000401050 4 X 0.5 8.0 32.5 99
031000511050 5G 0.5 8.5 38.7 114
031000501050 5 X 0.5 8.5 38.7 114
031000711050 7G 0.5 9.1 47.7 136
031000701050 7 X 0.5 9.1 47.7 136
031001211050 12G 0.5 11.3 75.2 198
031001201050 12 X 0.5 11.3 75.2 198
031001811050 18G 0.5 13.0 102.2 260
031002511050 25G 0.5 14.0 153.7 353
31003011050 30G 0.5 15.9 178.7 402
031004011050 40G 0.5 17.6 228.0 515
031000201075 2 x 0.75 7.7 27.5 91
031000311075 3G 0.75 8.1 36.2 103
031000301075 3 X 0.75 8.1 36.2 103
031000411075 4G 0.75 8.6 42.4 122
031000401075 4 X 0.75 8.6 42.4 122
031000511075 5G 0.75 9.3 48.7 142
031000501075 5 X 0.75 9.3 48.7 142
031000711075 7G 0.75 9.9 64.0 170
031000701075 7 X 0.75 9.9 64.0 170
031001211075 12G 0.75 12.5 101.1 275
031001201075 12 X 0.75 12.5 101.1 275
031001811075 18G 0.75 14.6 160.6 352
031001801075 18 X 0.75 14.6 160.6 352
031002511075 25G 0.75 15.8 214.1 448
031003411075 34G 0.75 19.0 279.0 627
031004001075 40 X 0.75 19.8 337.4 691
031004111075 41G 0.75 20.7 345.2 703
031000200001 2 x 1 8.1 32.0 101
031000310001 3G 1 8.4 42.2 117
031000300001 3 x 1 8.4 42.2 117
031000410001 4G 1 9.1 50.7 139
031000400001 4 x 1 9.1 50.7 139
031000510001 5G 1 9.7 61.3 163
031000710001 7G 1 10.4 79.5 197
031001210001 12G 1 13.2 146.2 300
031001610001 16G 1 14.7 185.5 375
031001810001 18G 1 15.4 202.5 402
031002510001 25G 1 16.7 271.5 525
031003410001 34G 1 20.2 354.0 700
031004110001 41G 1 22.0 437.1 880
031005010001 50G 1 23.1 521.9 990
031000201105 2 x 1.5 8.7 42.1 119
031000311105 3G 1.5 9.2 56.0 140
031000301105 3 x 1.5 9.2 56.0 140
031000411105 4G 1.5 9.9 69.1 167
031000401105 4 x 1.5 9.9 69.1 167
031000511105 5G 1.5 10.7 99.2 208
031000501105 5 x 1.5 10.7 99.2 208
031000711105 7G 1.5 11.5 124.6 256
031000701105 7 x 1.5 11.5 124.6 256
031001211105 12G 1.5 14.8 198.6 397
031001811105 18G 1.5 17.1 279.6 521
031002511105 25G 1.5 18.6 375.2 709
031003411105 34G 1.5 22.8 497.4 977
031004111105 41G 1.5 24.6 611.9 1168
031005011105 50G 1.5 25.9 730.1 1402
031000201205 2 x 2.5 10.1 61.2 166
031000311205 3G 2.5 10.7 99.1 208
031000411205 4G 2.5 11.5 121.1 253
031000511205 5G 2.5 12.5 146.4 274
031000711205 7G 2.5 13.5 192.3 350
031001211205 12G 2.5 17.7 304.4 585
031000200004 2 x 4 11.2 104.4 211
031000410004 4G 4 12.9 173.2 316
031000510004 5G 4 14.2 212.4 385
031000200006 2 x 6 13.1 141.6 296
031000410004 4G 6 15.3 250.2 450
031000510006 5G 6 16.7 303.7 544
031000200010 2 x 10 15.3 220.4 445
031000310010 3G 10 16.3 308.7 550
031000410010 4G 10 17.8 395.2 680
031000510010 5G 10 19.5 482.7 840
031000710010 7G 10 21.4 653.4 1068
031000200016 2 x 16 18.3 367.3 655
031000410016 4G 16 21.5 657.4 1021
031000510016 5G 16 23.6 807.2 1362
031000410025 4G 25 26.0 984.1 1618
031000510025 5G 25 31.6 1210.5 1980
031000410035 4G 35 32.0 1352.0 2235
031000510035 5G 35 35.5 1670.1 2760

3) JB-YCY

JB-YCY
Application :
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a high degree of interference protection. The dense screening assures disturbance-free transmission of all signals and impulses. The PVC-inner sheaths of these cables raise the mechanical strength. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid. These cables are suitable for flexible use for medium mechanical stresses with free movements. Standard Adapted to DIN/BS EN 50525-2-51.

Technical Data
  • Nominal Voltage: Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø
  • Test Voltage: 4000V
  • Breakdown Voltage: Min. 8000V
  • Mutual Capacitance (0.5 to 2.5 Sq. mm): core to core (approx.) - 150 nF/km
  • core to screen (approx.) - 270 nF/km



Part Number No. of Cores and Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Copper
Weight (kg/km)
030601010216 2 x 0.5 7.9 37 124
030601020116 3G 0.5 8.3 44 139
030601030116 4G 0.5 8.8 53 168
030601040116 5G 0.5 9.6 60 205
030601050116 7G 0.5 10.2 76 243
030601060216 2 x 0.75 8.3 44 140
030601070116 3G 0.75 8.7 54 160
030601080116 4G 0.75 9.5 66 198
030601090116 5G 0.75 10.1 78 239
030601100116 7G 0.75 10.8 99 286
030601110216 2 x 1 8.6 53 156
030601120116 3G 1 9.2 65 182
030601130116 4G 1 9.8 79 221
030601140116 5G 1 10.7 94 272
030601150116 7G 1 11.5 122 328
030601160216 2 x 1.5 9.7 66 198
030601170116 3G 1.5 10.2 87 231
030601180116 4G 1.5 11.1 106 286
030601190116 5G 1.5 12.4 129 368
030601200116 7G 1.5 13.2 165 442
030601210216 2 x 2.5 11.2 95 271
030601220116 3G 2.5 11.8 126 318
030601230116 4G 2.5 13.1 159 412
030601240116 5G 2.5 14.3 193 511
030601250116 7G 2.5 15.4 257 624
030601260116 4G 4 13.4 264 565
030601270116 5G 4 14.8 317 697
030601280116 4G 6 15.6 365 732
030601290116 5G 6 17 442 909
030601300116 3G 10 17.8 453 889
030601310116 4G 10 19.7 580 1125
030601320116 5G 10 21.6 711 1408
030601330116 3G 16 20.7 707 1274
030601340116 4G 16 22.6 917 1618
030601350116 5G 16 25.2 1128 2047
030601330116 3G 25 26.3 1064 1965
030601340116 4G 25 28.9 1386 2512
030601350116 5G 25 31.8 1708 3153
030601360116 3G 35 29.4 1453 2554
030601370116 4G 35 32.2 1900 3259
030601380116 5G 35 36.0 2347 4133
030601390116 3G 50 35.1 2048 3653
030601380116 4G 50 38.8 2688 4701
030601390116 4G 70 43.7 3732 6229
030601400116 4G 95 50.4 4915 8123
030601410116 4G 120 56.8 6198 10118

4) JB-YSY

JB-YSY
Application :
These cables are used as measuring and control cables in food processing industries, packaging industries, tool machinery, plant installation and power stations. The steel braid ensures best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion, but also notably improves the soldering properties. Standard Adapted to DIN/BS EN 50525-2-51

Technical Data
  • Nominal Voltage: Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range: Flexing -5°C to +70°C; Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø
  • Test Voltage: 4000V
  • Breakdown Voltage: Min. 8000V
  • Cable Construction



Part Number No. of Cores and Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
03070101021z 2 x 0.75 9.0 18 120
03070102011z 3G 0.75 9.4 27 138
03070103011z 4G 0.75 10.2 36 176
03070104011z 5G 0.75 10.9 44 204
03070105011z 7G 0.75 11.7 62 250
03070106011z 12G 0.75 14.4 107 398
03070107021z 2 x 1 9.3 24 129
03070108011z 3G 1 9.9 36 166
03070109011z 4G 1 10.6 47 196
03070110011z 5G 1 11.5 59 234
03070111011z 7G 1 12.3 83 290
03070112011z 25G 1 19.5 296 857
03070113021z 2 x 1.5 10.4 35 171
03070114011z 3G 1.5 10.9 52 205
03070115011z 4G 1.5 11.9 69 252
03070116011z 5G 1.5 13.1 87 307
03070117011z 7G 1.5 14.1 122 381
03070118011z 12G 1.5 17.3 208 618
03070119011z 18G 1.5 19.7 313 873
03070120011z 25G 1.5 22.6 434 1183
03070121011z 32G 1.5 24.7 556 1480
03070122021z 2 x 2.5 11.9 58 238
03070123011z 3G 2.5 12.5 87 285
03070124011z 4G 2.5 13.8 116 371
03070125011z 5G 2.5 15.0 145 442
03070126011z 7G 2.5 16.3 203 558
03070127021z 2 x 4 12.9 92 304
03070128011z 4G 4 15.0 184 477
03070129011z 5G 4 16.4 230 574
03070130011z 3G 6 15.2 207 492
03070131011z 4G 6 16.6 276 638
03070132011z 5G 6 18.1 345 770
03070133011z 4G 10 21.3 470 1042
03070134011z 5G 10 23.3 588 1270
03070135011z 4G 16 24.1 783 1479
03070136011z 5G 16 26.6 979 1858
03070137011z 4G 25 29.4 1218 2258
03070138011z 5G 25 32.6 1522 2831
03070139011z 4G 35 32.4 1715 2955
03070140011z 5G 35 36.0 2144 3711
03070141011z 4G 50 38.8 2461 4256

5) JZ-YSY

JZ-YSY
Application :
These cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided screen offers best possible protection against mechanical damage. The galvanised coating on the steel wire braiding not only helps protect against corrosion, but also notably improves the soldering performance. Standard Adapted to DIN VDE 0245, 0281, 0293, 0295.

Technical Data
  • Nominal Voltage: Uo / U 300 / 500V
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø
  • Test Voltage: 4000V
  • Breakdown Voltage: Min. 8000V
  • Cable Construction



Part Number No. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
03110101021z 2 x 0.5 8.0 9.5 99
03110102011z 3G 0.5 8.3 14.0 109
03110103011z 4G 0.5 8.8 19.0 123
03110104011z 5G 0.5 9.3 24.0 153
03110105011z 7G 0.5 9.9 33.5 171
03110106011z 10G 0.5 11.8 47.5 246
03110107011z 12G 0.5 12.1 57.0 263
03110108011z 14G 0.5 12.6 66.5 289
03110109011z 18G 0.5 13.8 85.5 313
03110110011z 21G 0.5 14.4 100.0 354
03110111011z 25G 0.5 14.8 118.5 391
03110112011z 30G 0.5 16.5 142.5 462
03110113011z 40G 0.5 18.3 190.0 582
03110114011z 61G 0.5 21.5 289.5 833
03110115021z 2 x 0.75 8.5 14.5 109
03110116011z 3G 0.75 8.9 21.5 123
03110117011z 4G 0.75 9.5 28.5 157
03110118011z 5G 0.75 10.1 36.0 174
03110119011z 7G 0.75 10.8 50.0 199
03110120011z 9G 0.75 12.5 64.0 261
03110121011z 12G 0.75 13.3 85.5 315
03110122011z 15G 0.75 14.5 107.0 363
03110123011z 18G 0.75 15.2 128.0 435
03110124011z 25G 0.75 16.4 178.0 507
03110125011z 34G 0.75 19.7 242.0 730
03110126011z 50G 0.75 22.2 356.0 901
03110127021z 2 x 1 8.9 19.0 120
03110128011z 3G 1 9.3 28.5 149
03110129011z 4G 1 9.9 38.0 172
03110130011z 5G 1 10.6 47.5 193
03110131011z 7G 1 11.3 66.5 232
03110132011z 8G 1 12.3 76.0 260
03110133011z 9G 1 13.2 85.5 300
03110134011z 12G 1 14.0 114.0 373
03110135011z 14G 1 14.6 133.0 406
03110136011z 18G 1 16.1 171.0 504
03110137011z 20G 1 16.8 190.0 522
03110138011z 25G 1 17.4 237.5 598
03110139011z 34G 1 20.8 322.5 762
03110140011z 41G 1 22.5 389.0 1013
03110141011z 50G 1 23.6 474.5 1105
03110142011z 65G 26.3 616.5 1426
03110143021z 2 x 1.5 9.6 29.0 159
03110144011z 3G 1.5 10.0 43.5 181
03110145011z 4G 1.5 10.7 58.0 206
03110146011z 5G 1.5 11.5 72.5 243
03110147011z 7G 1.5 12.3 101.0 302
03110148011z 8G 1.5 13.5 116.0 334
03110149011z 12G 1.5 15.5 173.5 449
03110150011z 14G 1.5 16.2 202.5 499
03110151011z 18G 1.5 17.8 260.0 593
03110152011z 25G 1.5 19.3 361.0 890
03110153011z 32G 1.5 22.1 462.5 1003
03110154011z 41G 1.5 25.1 592.5 1214
03110155011z 50G 1.5 26.4 722.5 1636
03110156011z 3G 2.5 11.5 61.0 228
03110157011z 4G 2.5 12.4 82.0 290
03110158011z 5G 2.5 13.3 102.0 341
03110159011z 7G 2.5 14.3 142.0 394
03110160011z 12G 2.5 18.3 248.0 627
03110161011z 18G 2.5 21.4 378.0 892
03110162011z 25G 2.5 23.1 525.0 1182
03110163011z 3G 4 12.7 96.0 296
03110164011z 4G 4 13.7 128.0 345
03110165011z 5G 4 14.9 159.5 410
03110166011z 7G 4 16.1 223.5 550
03110167011z 4G 6 16.0 191.5 540
03110168011z 5G 6 17.3 239.5 570
03110169011z 7G 6 18.8 335.0 725
03110170011z 4G 10 18.4 326.0 710
03110171011z 5G 10 20.1 407.5 865
03110172011z 7G 10 21.9 570.5 1100
03110173011z 4G 16 22.0 543.0 1050
03110174011z 5G 16 24.1 678.5 1280
03110175011z 4G 25 26.4 844.5 1620
03110176011z 5G 25 29.0 1055.5 1970
03110177011z 4G 35 30.6 1189.0 2205

6) STEEL BRAIDED YSY 1.1 KV

STEEL BRAIDED YSY 1.1 KV
Application :
These cables are used as power cables in building and commercial infrastructure, tool machinery, plant installation. The braided screen offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion, but also notably improves the soldering performance. The transparent sheath gives the cable in addition an optical revaluation. Standard The cables are provided with enhanced insulation thickness meeting 1.1kV rating.

Technical Data :
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -15°C to +70°C
  • Nominal Voltage: 1100V
  • Test Voltage: 4000V
  • Breakdown Voltage: Min. 8000V
  • Insulation Resistance: Min. 20 GΩ x cm
  • Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø Cable Construction



Part Number No. of Cores & Nominal
Cross Sectional Area(Sq. mm)
Approx.
Cable Diameter
(mm)
Approx.
Copper Weight
(kg/km)
Approx.
Copper Weight
(kg/km)
01200138xx1z 2 x 95 38.5 1711.8 3795.5
01200139xx1z 3 x 95 41.0 2567.7 4853.0
01200140xx1z 4 x 95 45.1 3423.6 6138.5
01200141xx1z 2 x 120 41.8 2168.3 4603.2
01200142xx1z 3 x 120 44.5 3252.5 5920.2
01200143xx1z 4 x 120 49.0 4336.6 7513.4
01200144xx1z 2 x 150 45.9 2674.7 5591.7
01200145xx1z 3 x 150 48.9 4012.1 7211.7
01200146xx1z 4 x 150 53.9 5349.4 9166.2
01200147xx1z 2 x 185 50.6 3320.2 6848.6
01200148xx1z 3 x 185 53.9 4980.3 8849.2
01200149xx1z 4 x 185 59.5 6640.4 11267.5
01200150xx1z 2 x 240 56.4 4279.6 8639.7
01200151xx1z 3 x 240 60.2 6419.3 11207.5
01200152xx1z 3 x 240 66.4 8559.1 14288.1

7) OZ-EB CY

OZ-EB CY
Application :
These cables are used for intrinsically safe circuits. For hazard prone areas cables with blue sheath are used for controlling and measuring requirements. These installations are not earthed and require a seperate power circuit. Tinned copper braid screen ensures disturbance free transmission of data and signals. Standard Adapted to DIN EN 60079-14: VDE 0165 Part 1.

Technical Data :
  • Nominal Voltage: UO / U 300 / 500V.
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø
  • Test Voltage: 3000V
  • Mutual Capacitance: core to core (approx.) - 140 nF/km
  • core to screen (approx.) - 185 nF/km
  • Inductance: 0.68 mH/km (approx.)
  • Cable Construction



Part Number No. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
031600201075 2 x 0.75 6.2 25 53.2
031600201075 3 x 0.75 6.5 31.3 64.0
031600201075 4 x 0.75 7.0 39.0 77.0
031600201075 4G 0.75 7.0 39.0 77.0
031600201075 5 x 0.75 7.7 47.2 93.4
031600201075 7 x 0.75 8.3 62.0 116.4
031600201075 12 x 0.75 10.9 98.9 189.7
031600201075 18 x 0.75 12.7 141.0 265
031600201075 25 x 0.75 14.8 210.6 363.6
031600201075 2 x 1 6.5 29.5 59.7
031600201075 3 x 1 6.8 38.9 73.6
031600201075 4 x 1 7.3 49.1 89
031600201075 5 x 1 8.1 58.4 108.1
031600201075 7 x 1 8.8 77.2 136.8
031600201075 12 x 1 11.5 125.5 223.3
031600201075 18 x 1 13.9 180 328.9
031600201075 25 x 1 15.9 266.1 439.8
031600201075 2 x 1.5 7.1 39.4 73.9
031600201075 3 x 1.5 7.5 51.7 92.7
031600201075 4 x 1.5 8.2 66.2 115.9
031600201075 5 x 1.5 8.9 80.9 138.7
031600201075 7 x 1.5 9.9 108 182.3
031600201075 12 x 1.5 13 175.1 298
031600201075 18 x 1.5 15.6 276 450.8
031600201075 25 x 1.5 17.9 377.6 596.4

8) JZ-HCH

JZ-HCH
Application :
Halogen-free cables for airports railway station, plant engineering and Industrial machinery, in EMC sensitive instruments. Tinned copper braid screen ensures disturbance free transmission of data and signals. Standard Adapted to EN 50525-3-11

Technical Data
  • Nominal Voltage: Uo / U 300 / 500V
  • Temperature Range: Flexing -15°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing approx. 15 x cable ø. Fixed installation approx. 6 x cable ø
  • Test Voltage: 4000V



Part Number

No. of Cores & Nominal
Cross Sectional Area (Sq. mm)

Approx. Cable
Diameter (mm)

Approx. Copper
Weight (kg/km)

Approx. Cable
Weight (kg/km)

031900201050

2 x 0.5

7.1

21.6

72

031900311050

3G 0.5

7.5

27.6

82

031900301050

3 X 0.5

7.5

27.6

82

031900411050

4G 0.5

8.0

32.5

97

031900401050

4 X 0.5

8.0

32.5

97

031900511050

5G 0.5

8.5

38.7

111

031900711050

7G 0.5

9.1

47.7

129

031901211050

12G 0.5

75.2

75.2

208

031900201075

2 x 0.75

27.5

27.5

86

031900311075

3G 0.75

36.2

36.2

99

031900301075

3 X 0.75

36.2

36.2

99

031900411075

4G 0.75

42.4

42.4

114

031900401075

4 X 0.75

42.4

42.4

114

031900511075

5G 0.75

48.7

48.7

130

031900501075

5 X 0.75

48.7

48.7

130

031900711075

7G 0.75

64.0

64.0

163

031900701075

7 X 0.75

64.0

64.0

163

031901211075

12G 0.75

101.1

101.1

258

031901811075

18G 0.75

160.6

160.6

372

031902511075

25G 0.75

214.1

214.1

493

031900200001

2 x 1

32.0

32.0

96

031900310001

3G 1

42.2

42.2

111

031900300001

3 X 1

42.2

42.2

111

031900410001

4G 1

50.7

50.7

127

031900400001

4 X 1

50.7

50.7

127

031900510001

5G 1

61.3

61.3

153

031900710001

7G 1

79.5

79.5

192

031901210001

12G 1

146.2

146.2

322

031901810001

18G 1

202.5

202.5

444

031902510001

25G 1

271.5

271.5

586

031904110001

41G 1

437.1

437.1

923

031900201105

2 x 1.5

42.1

42.1

116

031900311105

3G 1.5

56.0

56.0

136

031900301105

3 X 1.5

56.0

56.0

136

031900411105

4G 1.5

9.6

69.1

163

031900511105

5G 1.5

10.6

99.2

209

031900711105

7G 1.5

11.3

124.6

247

031901211105

12G 1.5

14.8

198.6

416

031901811105

18G 1.5

17.2

279.6

575

031902511105

25G 1.5

20.1

375.2

783

031900311205

3G 2.5

10.4

99.1

204

031900411205

4G 2.5

11.4

121.1

248

031900511205

5G 2.5

12.6

146.4

302

031900711205

7G 1.5

13.9

124.6

382

031901211205

12G 2.5

17.6

304.4

613


9) LIYCY

LIYCY
Application :
These cables are used for data and signal transmission application in the electronics of computer systems, electronic control equipment and measuring devices in the tool making and machine industries. The optimum screening substantially reduces the effect of electromagnetic interferences.

Technical Data
  • Standard: Based on VDE 0812
  • Voltage grade (not for power installation) : 0.14 mm² = 350 V; >/= 0.25 mm² = 500 V
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 15 x cable ø. Fixed installation 6 x cable ø
  • Test Voltage : Up to 0.25 mm²: 1200 V; > 0.34 mm² : 1500 V
  • Mutual capacitance (approx.)
  • Up to 0.34 mm²
  • C/C = 120 nF/km. C/S = 160 nF/km.
  • 0.5 mm² to 1.5 mm²
  • C/C = 160 nF/km. C/S = 240 nF/km
  • Inductance: Approx. 0.65 mH/km



Part Number No. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
031900201050 2 x 0.5 7.1 21.6 72
031900311050 3G 0.5 7.5 27.6 82
031900301050 3 X 0.5 7.5 27.6 82
031900411050 4G 0.5 8.0 32.5 97
031900401050 4 X 0.5 8.0 32.5 97
031900511050 5G 0.5 8.5 38.7 111
031900711050 7G 0.5 9.1 47.7 129
031901211050 12G 0.5 75.2 75.2 208
031900201075 2 x 0.75 27.5 27.5 86
031900311075 3G 0.75 36.2 36.2 99
031900301075 3 X 0.75 36.2 36.2 99
031900411075 4G 0.75 42.4 42.4 114
031900401075 4 X 0.75 42.4 42.4 114
031900511075 5G 0.75 48.7 48.7 130
031900501075 5 X 0.75 48.7 48.7 130
031900711075 7G 0.75 64.0 64.0 163
031900701075 7 X 0.75 64.0 64.0 163
031901211075 12G 0.75 101.1 101.1 258
031901811075 18G 0.75 160.6 160.6 372
031902511075 25G 0.75 214.1 214.1 493
031900200001 2 x 1 32.0 32.0 96
031900310001 3G 1 42.2 42.2 111
031900300001 3 X 1 42.2 42.2 111
031900410001 4G 1 50.7 50.7 127
031900400001 4 X 1 50.7 50.7 127
031900510001 5G 1 61.3 61.3 153
031900710001 7G 1 79.5 79.5 192
031901210001 12G 1 146.2 146.2 322
031901810001 18G 1 202.5 202.5 444
031902510001 25G 1 271.5 271.5 586
031904110001 41G 1 437.1 437.1 923
031900201105 2 x 1.5 42.1 42.1 116
031900311105 3G 1.5 56.0 56.0 136
031900301105 3 X 1.5 56.0 56.0 136
031900411105 4G 1.5 9.6 69.1 163
031900511105 5G 1.5 10.6 99.2 209
031900711105 7G 1.5 11.3 124.6 247
031901211105 12G 1.5 14.8 198.6 416
031901811105 18G 1.5 17.2 279.6 575
031902511105 25G 1.5 20.1 375.2 783
031900311205 3G 2.5 10.4 99.1 204
031900411205 4G 2.5 11.4 121.1 248
031900511205 5G 2.5 12.6 146.4 302
031900711205 7G 1.5 13.9 124.6 382
031901211205 12G 2.5 17.6 304.4 613

10) LIYCY (TP)

LIYCY (TP)
Application :
The high level of screening reduces substantially the effects of electrical disturbances. These cables are used for data & signal transmission. These cables are integral part of instrumentation in industries for precise signal and data transmission

Technical Data
  • Standard: Based on VDE 0812
  • Voltage grade (not for power installation) : 0.14 mm² = 350 V; >/= 0.25 mm² = 500V
  • Insulation Resistance: Min. 20 GΩ x cm
  • Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius: Flexing 15 x cable ø. Fixed installation 6 x cable ø
  • Test Voltage : Up to 0.25 mm²: 1200 V; > 0.34 mm² : 1500 V
  • Capacitance (approx. Value): Up to 0.34 mm²
  • C/C = 120 nF/km. C/S = 160 nF/km
  • 0.5 mm² to 1.5 mm²
  • C/C = 160 nF/km. C/S = 240 nF/km
  • Inductance: Approx. 0.65 mH/km



Part Number No. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
050401021014 10 x 2 x 0.14 8.2 43.3 97
050401221014 12 x 2 x 0.14 8.8 50.0 110
050401621014 16 x 2 x 0.14 9.8 63.9 138
050402021014 20 x 2 x 0.14 10.7 75.4 162
050402521014 25 x 2 x 0.14 11.7 92.1 195
050400221025 2 x 2 x 0.25 6.6 22.0 55
050400321025 3 x 2 x 0.25 6.7 26.8 64
050400421025 4 x 2 x 0.25 7.4 33.5 78
050400621025 6 x 2 x 0.25 8.6 45.6 104
050400821025 8 x 2 x 0.25 9.6 57.4 129
050401021025 10 x 2 x 0.25 10.5 69.4 154
050401221025 12 x 2 x 0.25 11.3 80.8 177
050401621025 16 x 2 x 0.25 12.7 102.8 223
050402521025 25 x 2 x 0.25 15.3 151.7 322
050400221034 2 x 2 x 0.34 6.8 25.9 60
050400321034 3 x 2 x 0.34 6.9 32.2 71
050400421034 4 x 2 x 0.34 7.6 40.4 87
050400621034 6 x 2 x 0.34 8.9 56.5 117
050400821034 8 x 2 x 0.34 9.9 71.8 146
050401021034 10 x 2 x 0.34 10.8 87.0 174
050401221034 12 x 2 x 0.34 11.6 101.2 200
050401621034 16 x 2 x 0.34 13.0 130.7 254
050402521034 25 x 2 x 0.34 15.8 195.1 371
050400221050 2 x 2 x 0.5 7.8 35.3 78
050400321050 3 x 2 x 0.5 7.9 44.7 94
050400421050 4 x 2 x 0.5 8.8 56.1 116
050400621050 6 x 2 x 0.5 10.3 78.6 158
050400821050 8 x 2 x 0.5 11.5 101.0 199
050401221050 12 x 2 x 0.5 13.6 143.3 276
050401621050 16 x 2 x 0.5 15.4 186.1 353
050400221075 2 x 2 x 0.75 8.3 45.6 92
050400321075 3 x 2 x 0.75 8.4 59.6 113
050400421075 4 x 2 x 0.75 9.4 76.4 141
050400521075 5 x 2 x 0.75 10.2 92.5 168
050400621075 6 x 2 x 0.75 11.0 108.7 195
050400821075 8 x 2 x 0.75 12.3 140.9 248
050401221075 12 x 2 x 0.75 14.6 202.0 348
050400220001 2 x 2 x 1 9.1 57.0 112
050400320001 3 x 2 x 1 9.3 75.7 139
050400420001 4 x 2 x 1 10.3 97.9 175
050400520001 5 x 2 x 1 11.3 118.7 209

11) LI2Y(ST)CY (TP)

LI2Y(ST)CY (TP)
Application :
These data cables with twisted pairs are used for interference-free transmission of data and signals over longer distances. The high transmission rate are suitable for RS 422 and RS 485 interfaces. This cable forms an integral part of supervisory control and data acquisition (SCADA) systems. These cables are suitable for fixed installations as well as for flexing applications, for free movement without forced motion and without tensile stress in dry and moist environment.

Technical Data
  • Standard: Based on VDE 0812
  • Voltage Grade (Not for power installation): Max. 250 V
  • Test Voltage: Core/core 2000 V. Core/screen 1000 V
  • Insulation Resistance: Min. 5000 GΩ x cm
  • Mutual Capacitance* : Max. 60 nF/km
  • Characteristic Impedance*: 100 Ω ±15
  • Cross-talk Attenuation : Upto 1 MHz min. 50 dB. Upto 10 MHz min. 40 dB
  • Inductance: Approx. 0.65 mH/km
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
  • Minimum Bending Radius : Flexing 15 x cable ø. Fixed installation 6 x cable ø Cable Construction



Part Number No. of Pairs & Nominal Cross Sectional Area (Sq. mm) Approx. Cable Diameter (mm) Approx. Copper Weight (kg/km)
Li2Y(St)CY (TP) Grey 50500221022 2 x 2 x 0.22 8.1 25
50500321022 3 x 2 x 0.22 8.2 29.1
50500421022 4 x 2 x 0.22 9.2 36
50500821022 8 x 2 x 0.22 12 60.7
50501021022 10 x 2 x 0.22 13.2 71.8
Li2Y(St)CYv (TP) 50500121034 2 x 2 x 0.34 8.6 31.7
50500221034 3 x 2 x 0.34 8.7 37.6
50500321034 4 x 2 x 0.34 9.7 46.4
50500421034 8 x 2 x 0.34 12.9 81.7
50500821034 10 x 2 x 0.34 14.1 96.7
50500221050 2 x 2 x 0.5 9.1 38.9
50500321050 3 x 2 x 0.5 9.2 48.1
50500421050 4 x 2 x 0.5 10.3 59.9
50500821050 8 x 2 x 0.5 13.7 106.6
50501021050 10 x 2 x 0.5 15 127.9
50500221075 2 x 2 x 0.75 9.7 50.1
50500321075 3 x 2 x 0.75 9.9 63.5
Li2Y(St)CYv (TP) 50500421075 4 x 2 x 0.75 11.1 80.8
50500821075 8 x 2 x 0.75 14.8 145.2
50501021075 10 x 2 x 0.75 16.3 178.3
50500220001 2 x 2 x 1 10.4 60.2
50500320001 3 x 2 x 1 10.6 81.8
50500420001 4 x 2 x 1 11.9 103
50500820001 8 x 2 x 1 15.9 189.1
50501020001 10 x 2 x 1 17.5 229.1
50600221022 2 x 2 x 0.22 8.4 25
50600321022 3 x 2 x 0.22 8.5 29.1
50600421022 4 x 2 x 0.22 9.5 36
50600821022 8 x 2 x 0.22 12.3 60.7
50601021022 10 x 2 x 0.22 13.5 71.8
50600221034 2 x 2 x 0.34 8.9 31.7
50600321034 3 x 2 x 0.34 9 37.6
50600421034 4 x 2 x 0.34 10 46.4
50600821034 8 x 2 x 0.34 13.2 81.7
50601021034 10 x 2 x 0.34 14.4 96.7
50600221050 2 x 2 x 0.5 9.4 38.9
50600321050 3 x 2 x 0.5 9.5 48.1
50600421050 4 x 2 x 0.5 10.6 59.9
50600821050 8 x 2 x 0.5 14 106.6
50601021050 10 x 2 x 0.5 15.3 127.9
50600221075 2 x 2 x 0.75 10 50.1
50600321075 3 x 2 x 0.75 10.2 63.5
50600421075 4 x 2 x 0.75 11.4 80.8
50600821075 8 x 2 x 0.75 15.1 145.2
50601021075 10 x 2 x 0.75 16.6 178.3
50600220001 2 x 2 x 1 10.7 60.2
50600320001 3 x 2 x 1 10.9 81.8
50600420001 4 x 2 x 1 12.2 103
50600820001 8 x 2 x 1 16.2 189.1
50601020001 10 x 2 x 1 17.8 229.1
Request A Quote