Thermal Overloade Relays-Tesys K Series (Direct Marketing)
Thermal Protection Adjustment |
For Use With | For Use With |
0.11...0.16 | LR2K0301 | |
0.16...0.23 | LR2K0302 | |
0.23...0.36 | LR2K0303 | |
0.36...0.54 | LR2K0304 | |
0.54...0.8 | LR2K0305 | |
0.8...1.2 | LR2K0306 | |
1.2...1.8 | LR2K0307 | |
1.8...2.6 | LR2K0308 | |
2.6...3.7 | LR2K0310 | |
3.7...5.5 | LR2K0312 | |
5.5...8 | LR2K0314 | |
8...11.5 | LR2K0316 | |
10...14 | LR2K0321 | |
12...16 | LR2K0322 |
Thermal Protection Adjustment | For Use With | For Use With |
LRD Model (Direct Mounting) | GV2L03, LE03, LC1D09...LC1D38 |
|
0.1...0.16 | LRD01 | |
0.16...0.25 | LRD02 | |
0.25...0.4 | LRD03 | |
0.4...0.63 | LRD04 | |
0.63...1 | LRD05 | |
1...1.6 | LRD06 | |
1.6...2.5 | LRD07 | |
2.5...4 | LRD08 | |
4...6 | LRD10 | |
5.5...8 | LRD12 | |
7...10 | LRD14 | |
9...13 | LRD16 | |
12...18 | LRD21 | |
16...24 | GV2L22, | LRD22 |
LC1D25...D38 | ||
23...32 | LC1D25...LC1D38, | LRD32 |
LC1D32 | ||
30...38 | LC1D32, LC1D38 | LRD35 |
23...32 | LC1D40A...D65a | LRD332 |
LC1D80...LC1D95 | LRD3353 | |
30...40 | LC1D40A...D65a | LRD340 |
30...40 | LC1D80...LC1D95 | LRD3355 |
37...50 | LC1D40A...D65a | LRD350 |
LC1D80...LC1D95 | LRD3357 | |
48...65 | LC1D40A...D65a | LRD365 |
62…80 | LC1D80A | LRD380 |
48...65 | LC1D80...LC1D95 | LRD3359 |
63...80 | LC1D80...LC1D95 | LRD3363 |
80...104 | LC1D80, LC1D95 | LRD3365 |
Current Range | For Use With | Reference* |
0.1....0.5 | LR9D01 | |
0.4....2.0 | LC1D09 - 38A Direct Mounting | LR9D02 |
1.6....8.0 | LR9D08 | |
6.4....32 | LR9D32 |
Thermal Protection Adjustment Range | Reference |
28…115 A | LR9G115 |
57…225 A | LR9G225 |
125…500 A | LR9G500 |
160…630 A | LR9G630* |
TeSys protect EOLR, EOCR Relay Electronic overload relay
Current Range | For Use With | Reference* |
LR9-D Electronic Protection Relays | LC1D09 - 38A DirectMounting | |
0.1....0.5 | LR9D01 | |
0.4....2.0 | LR9D02 | |
1.6....8.0 | LR9D08 | |
6.4....32 | LR9D32 | |
LR9-G Electronic Protection Relays | ||
28…115 | LR9G115 | |
57…225 | LC1G115 - 630A 8 Direct Mounting | LR9G225 |
125…500 | LR9G500 | |
160…630 | LR9G630 |
Current Range | EOCR SS Control Voltage | Reference* |
0.5-6 | 24-240V AC/DC | EOCRSS-05S |
3-30 | 24-240V AC/DC | EOCRSS-30S |
5-60 | 24-240V AC/DC | EOCRSS-60S |
Features \ product | LR9D / LR9G | SS / SSD | 3DM2/ FDM2 | 3MZ2 / FMZ2 / 3BZ2 / FBZ2 |
Precise Overload Protection (Inverse Time) |
||||
Over Current Protection (Defnite Time) | ||||
Selectable Trip Clas 5-30 | ||||
Current Unbalance Protection | LR9G Only |
|||
Locked Rotor, Phase Loss | * | |||
Under current Protection | LR9G Only |
|||
Ground Current Protection | 3CT | 2CT | 3CT | 3CT |
Current Measurement | # | |||
Current Display | $ | |||
Direct Mounting on Contactor | ||||
Fault History | ||||
Configurable protection functions |
Current Range | EOCR SSD Control Voltage |
Reference |
0.5-6 | 24-240V AC/DC | EOCRSSD-05S |
3-30 | 24-240V AC/DC | EOCRSSD-30S |
5-60 | 24-240V AC/DC | EOCRSSD-60S |