      Standard Sales Corporation

ComPact NSX

New generation of ComPacT MCCBs

  • Ethernet based communication system for monitoring, control, alarm notification for energy, asset and network management
  • Built-in energy metering with combined accuracy class of 2% for precise measurement
  • Wireless auxiliary Contacts accelerates overall wiring time: status communication is done very simply and commissioned wirelessly
  • Intelligent discrimination for continuity of service and enhanced discrimination by cascading
  • Patented reflex tripping, independent of other protection functions, ensures ultra fast tripping in the event of very high short circuit
  • Encapsulated roto-active double break contact system limits fault current for extended system life
  • Best in class electrical life (30k cycles for NSX 100 @ 440 V) reduces operational expenditure
  • High performance => Ics = Icu = 100kA @ 690V AC


ComPact Moulded Case Circuit Breaker

NSX Thermal Magnetic Trip Unit (TM-D)

  • ICS=Thermal Magnetic Trip Unit (TM-D)
  • Adjustable thermal setting 0.7 to 1x In
  • Adjustable magnetic setting 5 to 10 x Ir**
  • Transparent cover for trip units as standard
  • Breaking capacity enhancement upto 150kA with a higher capacity upstream (cascading).

Breaking Capacity Icu
as per IEC 60947-2
Rated Current Three Pole Reference Four Pole Reference
25kA 16A C10B3TM016 C10B6TM016
25A C10B3TM025 C10B6TM025
32A C10B3TM032 C10B6TM032
40A C10B3TM040 C10B6TM040
50A C10B3TM050 C10B6TM050
63A C10B3TM063 C10B6TM063
80A C10B3TM080 C10B6TM080
100A C10B3TM100 C10B6TM100
125A C16B3TM125 C16B6TM125
160A C16B3TM160 C16B6TM160
200A C25B3TM200 C25B6TM200
250A C25B3TM250 C25B6TM250
36kA 16A C10F3TM016 C10F6TM016
25A C10F3TM025 C10F6TM025
32A C10F3TM032 C10F6TM032
40A C10F3TM040 C10F6TM040
50A C10F3TM050 C10F6TM050
63A C10F3TM063 C10F6TM063 _
80A C10F3TM080 C10F6TM080
100A C10F3TM100 C10F6TM100
125A C16F3TM125 C16F6TM125
160A C16F3TM160 C16F6TM160
200A C25F3TM200 C25F6TM200
250A C25F3TM250 C25F6TM250
50kA 16A C10N3TM016 C10N6TM016
25A C10N3TM025 C10N6TM025
32A C10N3TM032 C10N6TM032
40A C10N3TM040 C10N6TM040
50A C10N3TM050 C10N6TM050
63A C10N3TM063 C10N6TM063
80A C10N3TM080 C10N6TM080
100A C10N3TM100 C10N6TM100
125A C16N3TM125 C16N6TM125
160A C16N3TM160 C16N6TM160
200A C25N3TM200 C25N6TM200
250A C25N3TM250 C25N6TM250
70kA 16A C10H3TM016 C10H6TM016
25A C10H3TM025 C10H6TM025
32A C10H3TM032 C10H6TM032
40A C10H3TM040 C10H6TM040
50A C10H3TM050 C10H6TM050
63A C10H3TM063 C10H6TM063
80A C10H3TM080 C10H6TM080
100A C10H3TM100 C10H6TM100
125A C16H3TM125 C16H6TM125
160A C16H3TM160 C16H6TM160
200A C25H3TM200 C25H6TM200
250A C25H3TM250 C25H6TM250

ComPact Moulded Case Circuit Breaker

  • NSX Micrologic 2 (μP -ASIC based)
  • Protection type LS0IN
  • Ics=100% Icu as per IEC 60947-2
  • Adjustable overload from 0.40 to 1 x In
  • Adjustable short circuit from 1.5 to 10 x Ir
  • Innovative front indication LEDS (Ready, Overload pre-alarm & overload)
  • Two frame sizes up to 630A
  • Breaking Capacity enhancement upto 150k with a higher capacity upstream (cascading)
  • Adjustable neutral protection - N, N/2 OFF for 4 pole MCCB

Breaking Capacity Icu
as per IEC 60947-2
Rated Current Three Pole Reference Four Pole Reference
25kA 40A C10B32D040 C10B42D040
100A C10B32D100 C10B42D100
160A C16B32D160 C16B42D160
250A C25B32D250 C25B42D250
36kA 40A C10F32D040 C10F42D040
100A C10F32D100 C10F42D100
160A C16F32D160 C16F42D160
250A C25F32D250 C25F42D250
400A C40F32D400 C40F42D400
630A C63F32D630 C63F42D630
50kA 40A C10N32D040 C10N42D040
100A C10N32D100 C10N42D100
160A C16N32D160 C16N42D160
250A C25N32D250 C25N42D250
400A C40N32D400 C40N42D400
630A C63N32D630 C63N42D630
70kA 40A C10H32D040 C10H42D040
100A C10H32D100 C10H42D100
160A C16H32D160 C16H42D160
250A C25H32D250 C25H42D250
400A C40H32D400 C40H42D400
630A C63H32D630 C63H42D630

NSX Micrologic 2 (μP -ASIC based)

Breaking Capacity Icu
as per IEC 60947-2
Rated Current Three Pole Reference Four Pole Reference
25kA 40A C10B32D040 C10B42D040
100A C10B32D100 C10B42D100
160A C16B32D160 C16B42D160
250A C25B32D250 C25B42D250
36kA 40A C10F32D040 C10F42D040
100A C10F32D100 C10F42D100
160A C16F32D160 C16F42D160
250A C25F32D250 C25F42D250
400A C40F32D400 C40F42D400
630A C63F32D630 C63F42D630
50kA 40A C10N32D040 C10N42D040
100A C10N32D100 C10N42D100
160A C16N32D160 C16N42D160
250A C25N32D250 C25N42D250
400A C40N32D400 C40N42D400
630A C63N32D630 C63N42D630
70kA 40A C10H32D040 C10H42D040
100A C10H32D100 C10H42D100
160A C16H32D160 C16H42D160
250A C25H32D250 C25H42D250
400A C40H32D400 C40H42D400
630A C63H32D630 C63H42D630

NSX Micrologic 2 (μP -ASIC based) / TMD / MA+ Shunt +GFP

  • 0ROTECTION TYPE L30)GN
  • ICS = 100% )CU AS PER )EC 60947-2
  • & AULT INDICATION FOR G & (LE$ TYPE) MEANT FOR HUMAN SAFETY
  • ADJUSTABLE OVERLOAD FROM 0.36 TO 1 X )N
  • ADJUSTABLE SHORT CIRCUIT FROM 1.5 TO 10 X )R
  • ADJUSTABLE EARTH FAULT SENSITIVITY SELECTION 10 TO 60%
  • INNOVATIVE FRONT INDICATION LE$’S (2EADY, / VERLOAD PRE-ALARM & / VERLOAD)
  • 4WO FRAME SIZES UP TO 630A
  • 3UITABLE FOR 3037 & 3047 ELECTRICAL DISTRIBUTION NETWORK
  • BREAKING CAPACITY ENHANCEMENT UPTO 150KA WITH A HIGHER CAPACITY upstream (Cascading)
  • ADJUSTABLE NEUTRAL PROTECTION - N, N/2, / && FOR 4 0OLE MCCB

MCCB Frame Relay Module
rated current
3 Ph + 3W
Reference
3 Ph + 4W
Reference
CVS/NSX100 32, 40, 50, 63, 80, 100 GFP11CT13P GFP11CT14P _
CVS/NSX 160 / 250 125, 160, 200, 250 GFP12CT23P GFP12CT24P
CVS/NSX 400 / 630 400, 630 GFP13CT33P GFP13CT34P

ComPact NSX - Moulded Case Circuit Breakers for Distribution Network


NSX Micrologic 6E

  • Ics = 100% Lcu as per IEC 60947-2
  • Breaking capacity enhancement upto 150k with a higher capacity upstream (cascanding)
  • External Neautral CT required for highly un-balanced TP-N system (*has to be ordered at extra price)
  • Adustable neutral protection- N N/2 , OFF and oversized neutral (Standard feature) for 4 pole MCCB
  • Adjustale short circuit form Ir 0.4 to 1 x In and tr = 0.5 to 16 s
  • Adjustable short circuit form Isd 1.5 to 10 x Ir and tsd I2t ON/OFF 0.1 to 0.4s
  • Adjustable earth fault 0.4 to 1 x In ( for In = 40 A ) & 0.2 to 1 x In (for In > 40A) and tg I2t ON/OFF 0.1to 0.4
  • Instantaneous protecrion li 1.5 x In to 15 x In ( 40 – 160 ), 12 x In (250 to 400 ) and 11 x In (630A)
  • Zone selective interlocking (ZSI) as standard

Breaking Capacity Icu
as per IEC 60947-2
Rated Current Three Pole
Reference
Four Pole
Reference
36kA 100A C10F36E100 C10F46E100
160A C16F36E160 C16F46E160
250A C25F36E250 C25F46E250
400A C40F36E400 C40F46E400
630A C63F36E630 C63F46E630
50kA 100A C10N36E100 C10N46E100
160A C16N36E160 C16N46E160
250A C25N36E250 C25N46E250
400A C40N36E400 C40N46E400
630A C63N36E630 C63N46E630
70kA 100A C10H36E100 C10H46E100
160A C16H36E160 C16H46E160
250A C25H36E250 C25H46E250
400A C40H36E400 C40H46E400
630A C63H36E630 C63H46E630

ComPact NSX - Circuit Breakers for Motor Protection

NSX Magnetic Trip Unit MA type

  • Ics =100% Icu as per IEC 60947-2
  • Adjustable magnetic setting Im 6 to 14 x In ( 2.5 to 100A) &9 to 14 x In (150 to 200)
  • Type 2 Co-ordination charts upto 110 Kw at 400V
  • Breaking Capacity enhancement upto 150KA with a higher capacity upstream (Cascading)
  • Adjustale neutral protection - N, N/2, OFF for 4 pole MCCB

Breaking Capacity Icuas  per IEC 60947-2r IEC 60947-2 Rated Current Three Pole
Reference
36kA   150A C16F3MA150
220A C25F3MA220
50kA   150A C16N3MA150
220A C25N3MA22
70kA 150A C16H3MA150
  220A C25H3MA220

ComPact NSX - Circuit Breakers for Motor Protection

MCCBs for DC Network Protection
16A to 1200A in Two frames sizes with Thermal Magnetic Trip Unit (TMD)

  • Up to 1200 A for ComPact NSX DC, protection is provided by thermal-magnetic trip units
  • TM-D up to 160 A: fixed thermal threshold and magnetic pick-up
  • TM-D up to 63 A: adjustable thermal threshold and fixed magnetic pick-up
  • TM-DC from 80 to 250 A: fixed or adjustable (for 200 and 250 A) magnetic pick- up and adjustable thermal threshold
  • TM-DC from 250 A to 1200 A adjustable magnetic pick-up and adjustable thermal threshold
  • TM-G, up to 250 A: adjustable thermal threshold and fixed low magnetic pick- up to protect long cables

Breaking Capacity Icuas  per IEC 60947-2r IEC 60947-2-2 Rated Current Three Pole
Reference
Four Pole
Reference
36kA 400A C40F3TM400D C40F4TM400D
500A C63F3TM500D C63F4TM500D
600A C63F3TM600D C63F4TM600D
100kA 400A C40S3TM400D C40S4TM400D
500A C63S3TM500D C63S4TM500D
600A C63S3TM600D C63S4TM600D

ComPact NSX - MCCB with Integrated Earth Leakage Protection

NSX Micrologic 4 Vigi

  • Standard protection for electrical distribution-overload, shortcircuit & neutral protection
  • Earth leakage protection-Adjustable leakage threshold (IΔn) and adjustable time delay threshold
    Sensitivity IΔn (A)
    Type A: 30mA - 100mA - 300mA - 500mA - 1A - 3A - 5A(for the ratings 40 to 250A)
    Type B: 300mA - 500mA - 1A - 3A - 5A - 10A (for the ratings 400 to 570A)
  • Alarming & Fault Indication

Breaking Capacity Icu
as per IEC 60947-2
Rated Current Three Pole
Reference
Four Pole
Reference
25KA 40A C10B34V040 C10B44V040
100A C10B34V100 C10B44V100
160A C16B34V160 C16B44V160
250A C25B34V250 C25B44V250
36KA 40A C10F34V040 C10F44V040
100A C10F34V100 C10F44V100
160A C16F34V160 C16F44V160
250A C25F34V250 C25F44V250
400A C40F34V400 C40F44V400
570A C63F34V570 C63F44V570
50KA 40A C10N34V040 C10N44V040
100A C10N34V100 C10N44V100
160A C16N34V160 C16N44V160
250A C25N34V250 C25N44V250
400A C40N34V400 C40N44V400
570A C63N34V570 C63N44V570
70KA  40A C10H34V040 C10H44V040
100A C10H34V100 C10H44V100
160A C16H34V160 C16H44V160
250A C25H34V250 C25H44V250
400A C40H34V400 C40H44V400
570A C63H34V570 C63H44V570

ComPact NSX - Accessories

Description Reference
Auxiliary contacts (changeover) Multifunction  
OF or SD or SDE or SDV 29450
OF or SD or SDE or SDV low leve 29452
SDE adaptor for trip unit TM or MA or Micrologic 2 $$ LV429451
SDx 2-Programmable Contacts for Micrologic  
SDx module 24/415 V AC/DC LV429532
SDTAM contactor tripping module for Micrologic 2- M/6 E-M  
SDTAM 24/415 V AC/DC overload fault indication LV429424

Voltage Releases

Description Shunt Release
Reference
Undervoltage
Reference
AC    
24 V 50/60 Hz LV429384 LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386 LV429406
220-240 V 50/60 Hz LV429387 LV429407
380-415 V 50 Hz LV429388 LV429408
525 V 50 Hz LV429389 LV429409
DC    
12 V LV429382 LV429402
24 V LV429390 LV429410
30 V LV429391 LV429411
48 V LV429392 LV429412
60 V LV429383 LV429403
125 V LV429393 LV429413
250 V LV429394 LV429414

Installation Accessories

Description 100/160/250A
Reference
400/630A
Reference
Spreaders & Phase Barrier    
Spreaders (Set of 3) 3P LV431563 32492
Spreaders (Set of 4) 4P LV431564 32493
Phase Barrier (Set of 6) * LV432570
Interlocking    
For Breaker with Rotary Handle LV429369 LV432621
For Breaker with Toggle LV429354 LV432614
Mechanical Interlocking with Base Plate 29349** 32609**
Locking of Rotary Handle    
Locking Device LV429344 LV432604
Ronis Keylock (1 Lock + 1 Key set) 41940 41940
Ronis Keylock (2 Locks + 1 Key set) 41950 41950
Profalux Keylock (1 Lock + 1 Key set) 42888 42888
Profalux Keylock (2 Locks + 1 Key set) 42878 42878

Motor Mechanism

Type Voltage 100/160A
Reference
250A
Reference
400/630A
Reference
Motor Mechanism Modules with SDE Adaptor (1)
AC
50/60 Hz
48-60 V LV429440 LV431548 LV432639
         
  110-130 V LV429433 LV431540 LV432640
  220-240 V LV429434 LV431541 LV432641
  380-415 V LV429435 LV431542 LV432642
  440-480 V LV429435 LV431542 LV432647
DC 24-30 V LV429436 LV431543 LV432643
  48-60 V LV429437 LV431544 LV432644
  110-130 V LV429438 LV431545 LV432645
  110-130 V LV429439 LV431546 LV432646

ComPact NSX - Accessories

Description 100/160/250A
Reference
400/630A
Reference
Locking of Motor Mechanism    
Keylock adaptor + Ronis keylock (special) LV429449 -
Locking Device - LV432649
Ronis Keylock - 41940
Profalux Keylock - 42888
Torque Limiting Screws (Set of 12) LV429513 LV432513

Monitoring and Control, test tools- ComPact and NSX100 - 630

Description Reference
ULP Display Module  
Switchboard front display module FDM121 TRV00121
ULP Wiring Accessories  
NSX cord L = 0.35 m LV434200
NSX cord L = 1.3 m LV434201
5 RJ45/RJ45 MALE Cord L = 1m TRV00810
10 Stacking connectors for COM interface TRV00217
ULP Communication Module  
IFM MODBUS Interface Module LV434000
BSCM ( Breaker Status and Control Module) LV434205 LV434205
Power Supply Modules  
External power supply module 24 V DC-1 A OVC IV  
200-240 V AC LV454444
Pocket battery for Micrologic NSX100-630 LV434206

ComPact NSX - Accessories

Description 100/160/250A
Reference
400/630A
Reference
Rotary Handles    
Standard direct black handle LV429337 LV432597
Standard extended rotary handle LV429338 LV432598
Plug in Base (Complete Kit)    
3 Pole LV429289 LV432538
4 Pole LV429290 LV432539
Draw-Out Chassis Kit    
3 Pole    
Plug In base LV429289 LV432538
Chassis Side Plate for base LV429282LV429282 LV432532
Chassis Side Plate for breaker LV429283 LV432533
4 Pole    
Plug In base LV429290 LV432539
Chassis Side Plate for base LV429282 LV432532
Chassis Side Plate for breaker LV429283 LV432533
Plug In / Withdrawable version Accessories    
Automatic Auxillairy Connectors    
1 9-wire fixed connector (for base) LV429273 LV429273
1 9-wire moving connector (for circuit breaker) LV429274 LV432523
1 support for 2 moving connectors LV429275 LV432525
Manual Auxillary Connectors    
9-wire manual auxiliary connector (fixed + moving) LV429272 LV429272

Unique Modular Ground Fault Protection

  • Earth Fault Protection for EasyPact CVS/ ComPact NSX MCCBs Modular Device for EasyPact CVS/ComPact NSX Range Moulded CaseCircuit Breakers
  • Adjustable earth fault sensitivity selection 10 to 60%
  • Adjustable time delay Inst/ 0.5 - 3 sec.
  • System healthiness check through LED indication
  • Individual fault indication for OL/SC, EF when used with ComPact NSX &EasyPactCVS (Optional)
  • Test facility to check healthiness of earth fault protection system without tripping MCCB
  • Suitable for 3P3W & 3P4W electrical distribution network

MCCB Frame Relay Module
rated current
3 Ph + 3W
Reference
3 Ph + 4W
Reference
CVS/NSX100 32, 40, 50, 63, 80, 100 GFP11CT13P GFP11CT14P
CVS/NSX 160 / 250 125, 160, 200, 250 GFP12CT23P GFP12CT24P
CVS/NSX 400 / 630 400, 630 GFP13CT33P GFP13CT34P

ComPacT NSX VigiPacT Add-on Module

MCCB Frame Three Pole (1)
Reference
Four Pole
Reference
NSX - 100/160 LV429488 LV429489
NSX - 250 LV429492 LV429493
NSX - 400/630 LV432464 LV432465