1) FR HSF



FR HSF
FR (Flame Retardant) insulation 70°C
Hazardous substance free
Does not propagate flame & fire.

Application : Flexible single core cable with Flame Retardant PVC insulation. This cable can be used in panels, cabinets, machines and internal wirings with switchgears, relays, controllers, equipments, controls units, etc.

Technical Data
  • Approvals: IS 694 marked, FIA / TAC
  • Cable Code: Y (FR)
  • oltage Grade: Up to and including 1100V
  • Conductor: Flexible electrolytic annealed plain copper, class 5, IS 8130
  • Insulation: FR (Flame Retardant) PVC, IS 5831
  • Packing: 200 mtr. In polybag packing or 180 mtr. coil packed in protective cartons Properties
  • Temperature range: -15°C to +70°C
  • Max. short circuit temperature rating: 160°C
  • Self-extinguishing and flame retardant according to IS 10810 P - 61
  • Free from 200+ hazardous substance (REACH Compliant) Cabel Design Parameters



  Part Number
Nominal Cross
Sectional Area
(sq, mm)
No of Strands/Max. strand dia. (mm) Nominal Insulation Thickness (mm ) Maximum Diameter Over insulation (mm) Max. current carrying capacity (A)
02090101xx20 0.5 16/0.2 0.6 2.6 5
02090102xx20 0.75 24/0.2 0.6 2.8 8
02090103xx20 1 32/0.2 0.6 3.0 13
02090104xx20 1.5 30/0.25 0.7 3.4 17
02090105xx20 2.5 50/0.25 0.8 4.1 24
02090106xx20 4 56/0.30 0.8 4.8 30
02090107xx20 6 84/0.30 0.8 5.3 38
02090108xx20 10 140/0.30 1.0 7.0 52
02090109xx20 16 126/0.40 1.0 8.1 70
02090110xx20 25 196/0.40 1.2 10.2 88
02090111xx20 35 276/0.40 1.2 11.7 112
02090112xx20 50 396/0.40 1.4 13.9 146
02090113xx20 70 360/0.50 1.4 16.0 216
02090114xx20 95 480/0.50 1.6 18.2 262
02090115xx20 120 608/0.50 1.6 20.2 310
02090116xx20 150 750/0.50 1.8 22.5 355
02090117xx20 185 931/0.50 2.0 24.9 415
02090118xx20 240 1200/0.50 2.2 28.4 500
02090119xx20 300 1500/0.50 2.4 31.0 550

2) RR KABEL FR-LSH

RR KABEL FR-LSH
FR-LSH (Flame Retardant Low Smoke and Halogen) insulation 70°C
Does not propagate flame & fire
Reduced Smoke and acid gas emission

Application : Flexible single core cable with FR-LSH (Flame Retardant Low Smoke and Halogen) PVC insulation. This cable can be used in panels, cabinets, machines and internal wirings with switchgears, relays, controllers, equipments, controls units, etc. specially in hazard prone areas. They also find their usage in flexible wiring installations in industrial and commercial areas with dense population.

Technical Data :
  • Approvals: IS 694 marked, FIA/TAC
  • Cable Code: Y (FR-LSH)
  • Voltage Grade: Up to and including 1100V
  • Conductor: Flexible electrolytic annealed plain copper, class 5, IS 8130
  • Insulation: Specially formulated FR-LSH (Flame Retardant Low Smoke and Halogen) PVC, IS 5831
  • Packing: 200 mtr. In polybag packing or 180 mtr. coil packed in protective cartons Properties

  • Temperature range: -15°C to +70°C
  • Reduced smoke emission provides higher visibility
  • Minimized acid gas generation
  • Max. short circuit temperature rating: 160°C
  • Self-extinguishing and flame retardant according to IS 10810 P - 61
  • Free from 200+ hazardous substance Cabel Design Parameters

Part Number
Nominal Cross
Sectional Area
(sq, mm)
No of Strands / Max. strand dia. (mm) Nominal Insulation Thickness (mm ) Maximum Diameter Over insulation (mm) Max. current carrying capacity (A)
02080101xx50 0.5 16/0.2 0.6 2.6 5
02080102xx50 0.75 24/0.2 0.6 2.8 8
02080103xx50 1 32/0.2 0.6 3.0 13
02080104xx50 1.5 30/0.25 0.7 3.4 17
02080105xx50 2.5 50/0.25 0.8 4.1 24
02080106xx50 4 56/0.30 0.8 4.8 30
02080107xx50 6 84/0.30 0.8 5.3 38
02080108xx50 10 140/0.30 1.0 7.0 52
02080109xx50 16 126/0.40 1.0 8.1 70
02080110xx50 25 196/0.40 1.2 10.2 88
02080111xx50 35 276/0.40 1.2 11.7 112
02080112xx50 50 396/0.40 1.4 13.9 146
02080113xx50 70 360/0.50 1.4 16.0 216
02080114xx50 95 480/0.50 1.6 18.2 262
02080115xx50 120 608/0.50 1.6 20.2 310
02080116xx50 150 750/0.50 1.8 22.5 355
02080117xx50 185 931/0.50 2.0 24.9 415
02080118xx50 240 1200/0.50 2.2 28.4 500
02080119xx50 300 1500/0.50 2.4 31.0 550

3) LS0H-FR

LS0H-FR
Flexible single core cable with Halogen Free Flame Retardant insulation. These are suitable for flexible installations preferably in panels, cabinets, machinaries, controllers, equipments used in chemical industries, oil and gas industries, in explosive or fire prone areas where safety is utmost important. They also find their usage in flexible wiring installations in industrial and commercial areas with dense population.

Technical Data
  • Approvals: IS 17048 marked, FIA / TAC
  • Cable Code: Z
  • Voltage Grade: Up to and including 1100V
  • Conductor: Flexible electrolytic annealed plain copper, class 5, IS 8130
  • Insulation: HFI-TP 70, Thermoplastic halogen free flame retardant.
  • Packing: 200 mtr. In polybag packing or 180 mtr. coil packed in protective cartons Properties

  • Temperature range: -15°C to +70°C
  • Max. short circuit temperature rating: 160°C
  • Self-extinguishing and flame retardant according to IS 10810 P - 61
  • Free from 200+ hazardous substance (REACH Compliant) Cabel Design Parameters

Part Number Nominal Cross
Sectional Area
(sq, mm)
No of Strands/Max. strand dia. (mm) Nominal Insulation Thickness (mm ) Maximum Diameter Over insulation (mm) Max. current carrying capacity (A)
02070101xx70 0.5 16/0.2 0.6 2.6 5
02070102xx70 0.75 24/0.2 0.6 2.8 8
02070103xx70 1 32/0.2 0.6 3.0 13
02070104xx70 1.5 30/0.25 0.7 3.4 17
02070105xx70 2.5 50/0.25 0.8 4.1 24
02070106xx70 4 56/0.30 0.8 4.8 30
02070107xx70 6 84/0.30 0.8 5.3 38
02070108xx70 10 140/0.30 1.0 7.0 52
02070109xx70 16 126/0.40 1.0 8.1 70
02070110xx70 25 196/0.40 1.2 10.2 88
02070111xx70 35 276/0.40 1.2 11.7 112
02070112xx70 50 396/0.40 1.4 13.9 146
02070113xx70 70 360/0.50 1.4 16.0 216
02070114xx70 95 480/0.50 1.6 18.2 262
02070115xx70 120 608/0.50 1.6 20.2 310
02070116xx70 150 750/0.50 1.8 22.5 355
02070117xx70 185 931/0.50 2.0 24.9 415
02070118xx70 240 1200/0.50 2.2 28.4 500
02070119xx70 300 1500/0.50 2.4 31.0 550

4) H05V-K & H07V-K

H05V-K & H07V-K
Application : Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed installation ducts. For use in public places such as: hospitals, schools, museums, airports, bus terminals, shops in general, etc., as well as in computer rooms, offices, production plants, switchboard wiring, laboratories, etc.
Standard
BS EN 50525-3-31.


Technical Data :

  • Nominal Voltage : H05Z1- K Uo / U 300 / 500V; H07Z1- K Uo / U 450 / 750V
  • Harmonized Designation : 0.5 mm² to 1 mm² – H05Z1- K, 1.5 mm2 to 240 mm2 - H07Z1- K
  • Temperature Range : -30°C to +70°C
  • Minimum Bending Radius :
  • Cable diameter ≤ 8 mm: 4 x outer diameter
  • Approx. diameter > 8 to 12 mm: 5 x outer diameter
  • Approx. diameter > 12 mm: 6 x outer diameter
  • Test Voltage: 2500V
  • Cable Construction
  • Conductor Class 5 flexible plain / metal coated stranded according to EN 60228. Insulation of thermoplastic halogen-free compound type TI7 to EN 50363-7.
  • Smoke density to acc. to EN 61034-2.
  • Halogen free acc. to EN 50525-1, EN 60754-1.
  • Corrosivity acc. to EN 60754-2.
  • Ozone resistant according to EN 60811-2-1 or HD 505.2.1.
  • Self-extinguishing and flame retardant according to EN 60332-1-2.
  • LSOH = Low Smoke Zero Halogen.

 

Part Numbers

Nominal Cross
Sectional Area
(Sq. mm)

Nominal Thickness
of Insulation (mm)

Mean Overall Diameter

Lower Limit (mm)

 

 

Upper Limit (mm)

 

Approx. Cable
Weight
(kg/km)

H05Z1-K

02050101xx7c

0.5

0.6

2.1

2.5

9

 

02050102xx7c

0.75

0.6

2.2

2.7

12

 

02050103xx7c

1

0.6

2.4

2.8

15

H07Z1-K

02050104xx7c

1.5

0.7

2.8

3.4

21

 

02050105xx7c

2.5

0.8

3.4

4.1

33

 

02050106xx7c

4

0.8

3.9

4.8

47

 

02050107xx7c

6

0.8

4.4

5.3

66

 

02050108xx7c

10

1.0

5.7

6.8

112

 

02050109xx7c

16

1.0

6.7

8.1

170

 

02050110xx7c

25

1.2

8.4

10.2

261

 

02050111xx7c

35

1.2

9.7

11.7

358

 

02050112xx7c

50

1.4

11.5

13.9

510

 

02050113xx7c

70

1.4

13.2

16.0

703

 

02050114xx7c

95

1.6

15.1

18.2

927

 

02050115xx7c

120

1.6

16.7

20.2

1170

 

02050116xx7c

150

1.8

18.6

22.5

1459

 

02050117xx7c

185

2.0

20.6

24.9

1776

 

02050118xx7c

240

2.2

23.5

28.4

2333


5) H05V2-K & H07V2-K

H05V2-K & H07V2-K
Application :
Heat resistant cable designed for internal wiring in switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
Standard
BS/VDE EN 50525-2-31.


Technical Data :

  • Voltage Rating: H05V2-K 0.5 to 1 mm² – 300 / 500V, H07V2-K 1.5 to 35 mm² – 450 / 750V
  • Temperature range: -30°C to +90°C
  • Minimum Bending Radius :
  • Cable diameter ≤ 8 mm: 4 x outer diameter
  • Approx. diameter > 8 to 12 mm: 5 x outer diameter
  • Approx. diameter > 12 mm: 6 x outer diameter
  • Test Voltage: 2500V
  • Construction
  • Conductor Class 5 flexible plain / metal coated stranded according to EN 60228.
  • Insulation PVC (Polyvinyl Chloride) TI3 to BS EN 50363 - 3. Properties

 

Part Numbers

Nominal Cross
Sectional Area
(Sq. mm)

Nominal Thickness
of Insulation
(mm)

Mean Overall Diameter

Lower Limit (mm)

 

Upper Limit (mm)

Approx. Cable
Weight
(kg/km)

H05V2-K

02030101xx3c

0.5

0.6

2.1

2.5

8.5

 

02030102xx3c

0.75

0.6

2.2

2.7

11.5

 

02030103xx3c

1

0.6

2.4

2.8

13.5

H07V2-K

02030104xx3c

1.5

0.7

2.8

3.4

20

 

02030105xx3c

2.5

0.8

3.4

4.1

4.1

 

02030106xx3c

4

0.8

3.9

4.8

46

 

02030107xx3c

6

0.8

4.4

5.3

65

 

02030108xx3c

10

1.0

5.7

6.8

110

 

02030109xx3c

16

1.0

6.7

8.1

167

 

02030110xx3c

25

1.2

8.4

10.2

257

 

02030111xx3c

35

1.2

9.7

11.7

358


6) H05Z-K & H07Z-K

H05Z-K & H07Z-K
Application :
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to be protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed installation ducts. The direct operating voltages is permitted up to 900 V against ground when they are used in rail-coaches. For the inner wiring of switch boards and distributors these are to be used with an alternating nominal voltage up to 1000V or a direct voltage up to 750V against ground.
Standard
BS EN 50525-3-41.


Technical Data

  • Nominal Voltage : H05Z-K Uo / U 300 / 500V, H07Z-K Uo / U 450 / 750V
  • Harmonised Designation: 0.5 mm² to 1 mm² - H05Z-K, 1.5 mm² to 240 mm² - H07Z-K
  • Temperature Range: -15°C to +90°C
  • Minimum Bending Radius :
  • Cable diameter ≤ 8 mm: 4 x outer diameter
  • Approx. diameter > 8 to 12 mm: 5 x outer diameter
  • Approx. diameter > 12 mm: 6 x outer diameter
  • Test Voltage: 2500V
  • Cable Construction


 

Part Numbers

Nominal Cross
Sectional Area
(Sq. mm)

Nominal Thickness
of Insulation
(mm)

Mean Overall Diameter
Lower Limit (mm)

Upper Limit (mm)

Approx. Cable
Weight
(kg/km)

 

02040101xx6c

0.5

0.6

1.9

2.4

9

H05Z-K

02040102xx6c

0.8

0.6

0.8

2.6

12

 

02040103xx6c

1

0.6

2.2

2.8

15

H07Z-K

02040104xx6c

1.5

0.7

1.5

3.5

21

 

02040105xx6c

2.5

0.8

3.4

4.3

33

 

02040106xx6c

4

0.8

3.9

4.9

47

 

02040107xx6c

6

0.8

4.4

5.5

66

 

02040108xx6c

10

1.0

5.7

7.1

112

 

02040109xx6c

16

1.0

6.7

8.4

169

 

02040110xx6c

25

1.2

8.4

10.6

260

 

02040111xx6c

35

1.2

9.7

12.1

358

 

02040112xx6c

50

1.4

11.5

14.4

509

 

02040113xx6c

70

1.4

13.2

16.61

701

 

02040114xx6c

95

1.6

15.1

18.8

925

 

02040115xx6c

120

1.6

16.7

20.9

1168

 

02040116xx6c

150

1.8

18.6

23.3

1456

 

02040117xx6c

185

2.0

20.6

25.8

1773

 

02040118xx6c

240

2.2

23.5

29.4

2329


7) H05Z1-K & H07Z1-K

H05Z1-K & H07Z1-K

Application :
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed installation ducts. For use in public places such as: hospitals, schools, museums, airports, bus terminals, shops in general, etc., as well as in computer rooms, offices, production plants, switchboard wiring, laboratories, etc.
Standard
BS EN 50525-3-31.

Technical Data
  • Nominal Voltage : H05Z1- K Uo / U 300 / 500V; H07Z1- K Uo / U 450 / 750V
  • Harmonized Designation : 0.5 mm² to 1 mm² – H05Z1- K, 1.5 mm2 to 240 mm2 – H07Z1- K
  • Temperature Range : -30°C to +70°C
  • Minimum Bending Radius :
  • Cable diameter ≤ 8 mm: 4 x outer diameter
  • Approx. diameter > 8 to 12 mm: 5 x outer diameter
  • Approx. diameter > 12 mm: 6 x outer diameter
  • Test Voltage: 2500V
  • Cable Construction
  • Conductor Class 5 flexible plain / metal coated stranded according to EN 60228. Insulation of thermoplastic halogen-free compound type TI7 to EN 50363-7.

Properties

  • Smoke density to acc. to EN 61034-2.
  • Halogen free acc. to EN 50525-1, EN 60754-1.
  • Corrosivity acc. to EN 60754-2.
  • Ozone resistant according to EN 60811-2-1 or HD 505.2.1.
  • Self-extinguishing and flame retardant according to EN 60332-1-2.
  • LSOH = Low Smoke Zero Halogen. Cabel Design Parameters

 

Part Numbers

Nominal Cross
Sectional Area
(Sq. mm)

Nominal Thickness
of Insulation
(mm)

Mean Overall Diameter

Lower Limit (mm)

 

 

Upper Limit (mm)

Approx. Cable
Weight
(kg/km)

H05Z1-K

02050101xx7c

0.5

0.6

2.1

2.5

9.5

 

02050102xx7c

0.75

0.6

2.2

2.7

12.5

 

02050103xx7c

1

0.6

2.4

2.8

15.5

H07Z1-K

02050104xx7c

1.5

0.7

2.8

3.4

21.5

 

02050105xx7c

2.5

0.8

3.4

4.1

33.5

 

02050106xx7c

4

0.8

3.9

4.8

48

 

02050107xx7c

6

0.8

4.4

5.3

67

 

02050108xx7c

10

1.0

5.7

6.8

113

 

02050109xx7c

16

1.0

6.7

8.1

171

 

02050110xx7c

25

1.2

8.4

10.2

262

 

02050111xx7c

35

1.2

9.7

11.7

360

 

02050112xx7c

50

1.4

11.5

13.9

513

 

02050113xx7c

70

1.4

13.2

16.0

705

 

02050114xx7c

95

1.6

15.1

18.2

931

 

02050115xx7c

120

1.6

16.7

20.2

1175

 

02050116xx7c

150

1.8

18.6

22.5

1264

 

02050117xx7c

185

2.0

20.6

24.9

1783

 

02050118xx7c

240

2.2

23.5

28.4

2341


8) BS 6231 CK 90°C

BS 6231 CK 90°C

Application :
High temperature, flame retardant cable designed for use in switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
Standard
BS6231 Type CK.

Technical Data
  • Voltage Rating: 600 / 1000V
  • Temperature Rating : 90°C (105°C for 15,000 hours)
  • Minimum Bending Radius :
  • Cable diameter ≤ 8 mm: 4 x outer diameter.
  • Approx. diameter > 8 to 12 mm: 5 x outer diameter
  • Approx. diameter > 12 mm: 6 x outer diameter
  • Test Voltage: 4000V
  • Construction
  • Conductor: Conductor Class 5 flexible plain/metal coated stranded according to EN 60228 cl. 5.
  • Insulation: PVC (Polyvinyl Chloride) TI3 to BS EN 50363-3. Properties

Part Numbers   Nominal Cross
Sectional Area
(Sq. mm)
  Nominal Thickness
of Insulation
(mm)
  Mean Overall Diameter

Lower Limit (mm)
    Upper Limit(mm)   Approx. Cable
Weight
(kg/km)
02060101xx3c 0.5 0.8 2.4 3.0 11
02060102xx3c 0.75 0.8 2.6 3.1 14
02060103xx3c 1 0.8 2.7 3.3 16
02060104xx3c 1.5 0.8 3.0 3.6 21
02060105xx3c 2.5 0.8 3.4 4.1 32
02060106xx3c 4 0.8 3.9 4.8 46
02060107xx3c 6 0.8 4.4 5.3 64
02060108xx3c 10 1.0 5.7 7.2 109
02060109xx3c 16 1.0 6.7 9.0 166
02060110xx3c 25 1.2 8.4 11.5 256
02060111xx3c 35 1.2 9.7 12.5 352
02060112xx3c 50 1.4 11.5 15.4 501
02060113xx3c 70 1.4 13.2 17.5 692
02060114xx3c 95 1.6 15.1 19.2 914
02060115xx3c 120 1.6 16.7 21.2 1155
02060116xx3c 150 1.8 18.6 23.9 1441
02060117xx3c 185 2.0 20.6 25.9 1754
02060118xx3c 240 2.2 23.5 28.9 2305

9) UL 1015

UL 1015

Application :
These cables are used for internal wiring of panels and electrical equipment. These are used as connection wire in machines laid in protective tubes and flexible pipes and also for motors and transformers.

Technical Data
  • Standard: UL - Std. 758, CSA C 22.2 No. 210
  • Nominal Voltage: 600V
  • UL: type AWM 105°C 600V
  • CSA: type AWM 105°C 600V
  • Test Voltage (Spark Test):
  • AWG 24: 4kV
  • AWG 22 and 20: 5kV
  • AWG 18 to 16: 6kV
  • ≥ AWG 8: 7.5kV

Temperature range:

  • Flexing -5°C to +105°C. Fixed installation -20°C to +105°C
  • Temperature at Conductor: Max. UL and CSA : +105°C
  • Bending Radius: Flexing 10 x cable ø’. Fixed installation 5 x cable ø Cable Construction
  • Annealed plain or tinned stranded copper conductor.
  • PVC - core insulation according to UL – Standard 1581, Class 43 Tab. 50.182, heat and damp resistant.
  • Properties - Conditionally resistant to oils, solvents, acids and dyes.
  • PVC self - extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2

Part Number AWG No. No. of Cores and
Nominal Cross Sectional
(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
06020101xx30 24 1 x 0.21 2.2 2.1 7
06020102xx30 22 1 x 0.33 2.4 3.5 9
06020103xx30 20 1 x 0.52 2.5 5.2 11
06020104xx30 18 1 x 0.82 2.8 8.3 16
06020105xx30 16 1 x 1.32 3.1 13.5 22
06020106xx30 14 1 x 2.08 3.5 20.4 31
06020107xx30 12 1 x 3.31 4.0 32.5 45
06020108xx30 10 1 x 5.26 4.6 51.7 68
06020109xx30 8 1 x 8.35 6.2 82.5 113
06020110xx30 6 1 x 13.3 8.0 132.1 184
06020111xx30 4 1 x 21.14 9.4 207.3 275
06020112xx30 3 1 x 26.65 10.2 262 339
06020113xx30 2 1 x 33.61 11.0 330.3 416
06020114xx30 1 1 x 42.38 13.0 416.9 543
06020115xx30 1/0 1 x 53.47 13.8 524.6 659
06020116xx30 2/0 1 x 67.4 15.2 661 820
06020117xx30 3/0 1 x 85.0 16.5 832.3 1013
06020118xx30 4/0 1 x 107.2 18.0 1050.9 1257
06020119xx30 250 kcmil 1 x 127 20.0 1245 1507
06020120xx30 300 kcmil 1 x 152 21.4 1489.8 1780
06020121xx30 350 kcmil 1 x 178 22.6 1734.6 2048
06020122xx30 400 kcmil 1 x 203 24.0 1989.9 2338
06020123xx30 500 kcmil 1 x 254 26.0 2479.5 2868

10) UL 1007

UL 1007
Application :
These cables are used for internal wiring of switchboards, electronic and electrical equipment, e.g. households, radio of televisions, monitor and control desks.

Technical Data
  • Standard: UL - Std. 758, CSA C 22.2 No. 210
  • Nominal Voltage: 300V
  • Test Voltage: 2000V Test Voltage (Spark Test)
  • AWG 26-20: 4kV, AWG 10 -18 : 5kV
  • Temperature Range: Flexible -5°C to +80°C. Fixed installation -20°C to + 80°C CSA – AWM I A/B
  • Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø Cable Construction
  • Annealed plain or tinned stranded copper conductor.
  • PVC – core insulation according to UL - Standard 1581, Class 43 Tab. 50.182, heat and damp resistant.

Properties

  • Conditionally resistant to oils, solvents, acids and dyes
  • PVC self - extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2


Part Number AWG No. No. of Cores and
Nominal Cross Sectional
(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
06030101xx30 26 1 x 0.14 1.3 1.4 3.0
06030102xx30 24 1 x 0.21 1.5 2.1 4.3
06030103xx30 22 1 x 0.33 1.6 3.5 5.8
06030104xx30 20 1 x 0.52 1.9 5.2 8.0
06030105xx30 18 1 x 0.82 2.2 8.3 12.0
06030106xx30 16 1 x 1.32 2.5 13.5 18.4

11) UL 1569

UL 1569
Application :
These cables are used for internal wiring of switchboards, electronic and electrical equipment, e. g. households, radio of televisions, monitor and control desks.

Technical Data
  • Standard: UL - Std. 758, CSA C 22.2 No.210
  • Nominal Voltage: 300V
  • Test Voltage: 2000V Test Voltage (Spark Test)
  • AWG 26-20: 4kV, AWG 10 -18: 5kV
  • Temperature Range: Flexible -5°C to + 105°C.
  • Fixed installation - 20°C to + 105°C CSA – AWM I A/B
  • Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø Cable Construction
  • Annealed plain or tinned stranded copper conductor.
  • PVC - core insulation according to UL - Standard 1581, Class 43 Tab. 50.182, heat and damp resistant.

Properties

  • Conditionally resistant to oils, solvents, acids and dyes.
  • PVC self - extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2


Part Number AWG No. No. of Cores and
Nominal Cross Sectional(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
06040101xx30 26 1 x 0.14 1.3 1.4 3.0
06040102xx30 24 1 x 0.21 1.5 2.1 4.3
06040103xx30 22 1 x 0.33 1.6 3.5 5.8
06040104xx30 20 1 x 0.52 1.8 5.2 8.0
06040105xx30 18 1 x 0.82 2.1 8.3 12.0
06040106xx30 16 1 x 1.32 2.5 13.5 18.4
06040107xx30 14 1 x 2.08 3.0 20.4 27.3
06040108xx30 12 1 x 3.31 3.5 32.5 41.3
06040109xx30 10 1 x 5.26 4.1 51.7 62.8

12) UL 1275

UL 1275
Application :
PVC-insulated heavy wall lead wire, for use as hook – up wire and for internal wiring on refrigeration equipments.

Technical Data
  • Standard: UL - Std. 758, CSA C 22.2 No. 210
  • Temperature Range: -20°C to 105°C
  • Nominal Voltage: 600V
  • Test Voltage (Spark Test):
  • AWG 18 to 16 : 6kV
  • ≥ AWG 8: 7.5kV
  • Bending Radius: Fixed installation 5 x cable ø Cable Construction Annealed plain or tinned stranded copper conductor.
  • PVC – core insulation Type TW, Recognized Component QMTT2 heat and damp resistant.


Part Number AWG No. No. of Cores and
Nominal Cross Sectional
(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
06050101xx30 18 1 x 0.82 4.3 8.3 27.4
06050102xx30 16 1 x 1.32 4.6 13.5 35.1
06050103xx30 14 1 x 2.08 5.0 20.4 44.9
06050104xx30 12 1 x 3.31 5.5 32.5 60.6
06050105xx30 10 1 x 5.26 6.1 51.7 84.5

13) UL 3289/3321/3173/3271/3344 XLPE CABLE

UL 3289/3321/3173/3271/3344 XLPE CABLE
Application :
These cables have excellent resistance to abrasion, deformation, cut-through and chemical attack. This wire is widely used in appliances, transformers, electrical heating, motors, ballast, lighting and cooking equipment. Suitable for use as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 130°C Class Motor Leads. Economical replacement for silicone rubber/glass braid insulated wire and cable.

Technical Data
  • Standard: UL - Std. 758. Complies to CSA No. 22.2 210 and 127
  • Nominal Voltage: 600V
  • Test Voltage (Spark Test):
  • AWG 22 and 20: 5kV
  • AWG 18 to 10: 6kV
  • ≥ AWG 8: 7.5kV
  • Temperature Range: Flexible -5°C to +150°C. Fixed installation -50°C to +150°C
  • Temperature at Conductor: Max. UL : +150°C
  • Bending Radius: Approx. 5 x cable ø

Temperature range:

  • Annealed plain or tinned stranded copper conductor.
  • XLPE insulation according to UL- Std. 1581 Table 50.232, Complies to CSA No. 22.2 210 and 127.

AWG Metric
Cross Section
Area (Sq. mm)
No. of
Strands/Strand Dia.
(mm)
Max. DC Conductor
Resistance for
ABC @ 20°C (Ω/km)
Max. DC Conductor
Resistance for
ATC @ 20°C (Ω/km)
Insulation
Thickness
(mm)
Nominal Cable
Diameter (mm)
21 0.50 16/0.2 43.6 46.9 0.762 2.4
19 0.75 24/0.2 27.4 29.1 0.762 2.6
18 1.00 32/0.2 21.8 23.2 0.762 2.8
16 1.50 30/0.25 13.7 14.6 0.762 3.1
14 2.50 50/0.25 8.62 8.96 0.762 3.5
12 4.00 56/0.3 5.43 5.64 0.762 4.0
10 6.00 84/0.3 3.409 3.546 0.762 4.6
8 10.00 140/0.3 2.144 2.23 1.143 6.1
6 16.00 126/0.4 1.348 1.403 1.524 7.9
4 25.00 196/0.4 0.8481 0.882 1.524 9.1
2 35.00 276/0.4 0.5335 0.5548 1.524 10.7
1 50.00 296/0.4 0.423 0.4398 2.032 12.8
2/0 70.00 360/0.5 0.266 0.2766 2.032 14.8
3/0 95.00 480/0.5 0.211 0.2194 2.032 16.2
4/0 120.00 608/0.5 0.1673 0.1722 2.032 17.7